3/19/2021 0 Comments Baumer Encoder Manual
Please check your inbox, and if you cant find it, check your spam folder to make sure it didnt end up there.It is used to determine angular positions and revolutions and to prepare and supply measured values in the form of electrical output signals for control systems.The encoder must not be used for any other purpose.
In this case, safe and reliable operation is no longer guaranteed. Operating environment and wiring have an impact on the electromagnetic compatibility of the encoder. Install encoder and supply cables separately or far away from sources with high emitted interference (frequency converters, contactors, etc). The braided shield must be connected to the cable gland or connector. Ideally, aim at dual connection to protective earth (PE), i.e. Depending on what is required of the encoder, the basic encoder and bus covers can be combined at will with the selected bus system. The multiturn encoder features a 16 bit resolution respectively 65536 turns, or a 14 bit resolution corresponding to 16384 turns (multivo Plus). The units have left the manufacturing plant ready to operate and in safe condition. In addition to the operating manual, the generally applicable legal and other binding regulations for accident prevention and environmental protection must be observed and ensured. Installation work may only be carried out by appropriately trained experts. Following commissioning, familiarize yourself with the use of the units in Chapter 4 Operator Level. Maintenance and repair work may only be carried out by appropriately trained experts. The PTBapproved system for example provides a chart printer model STAR SP298. Running values and the set parameters remain even after power failure. Do not otherwise assign contacts that have been left unassigned ex factory. We recommend to screen all encoder terminal leads and to ground the shield on one side. Shields on both sides are recommended in case of RF interference or in case of equipotential bonding over long distances. Do not utilize the voltage supply for parallel supply of drives, shields, magnetic valves, etc. Supplying lines must be separated from lines providing load current. EN 61010 specifies that 8 A150 VA (W) must never be exceeded in the event of a fault. Terminals 10 and 11 are configured as NC or NO contacts in accordance with the purchase order specification. The signal outputs can be assigned in accordance with the adjoining wiring diagram. Terminals 12 (track A) and 13 (track B) are pulse inputs for the main counter (XP) counting function. Depending on what is set in the programming mode (line 40), terminal 15 serves as a starting input for the operating hours counter. Terminal 16 (track B1) is the pulse input for the secondary counter (XB). The method of resetting is set in the programming mode (lines 29, 30). The maximum counter frequency is selected in the programming mode (line 26).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |